Bulbs.com

243 Stafford St.

Worcester, MA 01603

Tel. 1 (888) 455-2800

Fax 1.508.363.2900

www.bulbs.com

The Business Lighting Experts

Green Creative 9W 2 or 4 Pin 3500K G24 Base Omni Directional Hybrid LED Bulb

SKU: 35002 | Ordering Code: 9PLO/835/HYBM  | UPC: 790492350027

$21.99each
Add to Cart
Save to BulbTrack ?

Quickly and easily order the products you have purchased in the past or plan to order in the future by simply adding them to your My BulbTrack page.

Once a product has been added to My BulbTrack, ordering it is as easy as entering the quantity or clicking on the product image. You can even add notes to each product to record where it is used in your business or home.

On BackorderTypically ships in 7-10 business days
We may already have more on the way or, in most cases, we can ship directly from the manufacturer. Call 888-455-2800 and one of our Lighting Specialists will help to complete your order.

Add 5 to your cart to get free ground shipping *

Options

Brightness (Lumens)
820 1170
Color Temperature (Kelvin)
Color Temperature Guide 2700 3000 3500 4000

Product Highlights

  • Estimated life of 45.7 years based on 3 hours use per day
  • No lead or mercury means easy and environmentally safe disposal
Description

Lighting Facts Per Bulb

Brightness 1170 lumens
Estimated Yearly Energy Cost $1.08
Based on 3 hrs/day, 11¢/kWh
Cost depends on rates and use
Life
Based on 3 hrs/day45.7 years
Light Appearance
WarmCool
3500 K
Energy Used9 watts

The omni directional non-dimmable LED lamp from Green Creative is a line driven (ballast bypass) or ballast compatible (plug 'n play) LED replacement for a 26 watt CFL with a 2-pin or 4-pin G24d, GX24d, G24Q or GX24q socket. 

  • Omni directional light distribution equivalent to fluorescent lamps
  • May be installed horizontally or vertically
  • Hybrid installation - ballast bypass or plug 'n play
  • Replaces G24d and GX24d (2-pin), G24q and GX24q (4-pin) 26W CFL lamps
  • Compatible with magnetic ballasts for plug 'n play applications
  • Built-in universal voltage driver for bypass applications
  • Lamp CCT falls within 4 SDCM for consistent CCT
  • Horizontal installation
    • Lamp compartment dimensions - 6 1/8" diameter; 4 3/4" height
    • Maximum lamps in luminaire - 2
    • Lampholder-to lampholder spacint - 3/8"
  • Vertical installation
    • Lamp compartment dimensions - 6 5/16" diameter; 9 1/16" height
    • Maximum lamps in luminaire - 1

Do not "hot swap" this lamp. Turn off the fixture before replacing the existing bulb. If the lamp does not light when the luminaire is turned on, remove the lamp from the luminaire. If the lamp or luminaire exhibits undesirable operation (buzzing, flickering, etc.) immediately turn off the power and remove the lamp.

Full Specs

Brand

Green Creative

Model Number

9PLO/835/HYBM
Energy Used
A rating, expressed in watts, to indicate the rate at which a lamp consumes energy. Also known as wattage value.
9 Watts
Fluorescent Equivalent
The total wattage of fluorescent lamps in a fixture that this fixture replaces.
26
Volts
A measure of "electrical pressure" between two points. The voltage specification of an incandescent lamp is the electrical "pressure" required to drive it at its designed point. The "voltage" of a ballast (e.g. 120 V) refers to the line voltage coming from the power source and is connected to the ballast.
120-277
Base
The end (or ends) of the lamp that fits into the socket.
G24q/GX24q/G24d/GX24d
Bulb Shape
The description of the general appearance of a lamp/bulb consists of a letter(s) followed by a number. The letter indicates the shape of the bulb and the number relates to the diameter of the bulb in eighths of an inch. For example, a common household bulb is the A-19. The bulb is "A" shape and the diameter would be nineteen 8ths of an inch, or 2 3/8".
Triple Twin Tube
Bulb Color
The color of the light produced by a bulb
Neutral White
CRI
Color Rendering Index is an international system used to rate a lamp's ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer and more accurately colors generally appear. CRI differences among lamps are not usually visible to the eye unless the difference is more than 3-5 points.
82
Color Temperature (Kelvin)
An expression of the hue of the light emitted, measured in degrees Kelvin. Usually expressed by a four digit number followed by (k), such as 2700k. Higher temperatures indicate whiter, "cooler" colors, while lower temperatures indicate yellower, "warmer" colors. Some common Kelvin temperature benchmarks are 2700k (warm white), 3500k (neutral white), 4100k (cool white), 5000k (bright white), and 6500k (daylight).
3500
Brightness (Lumens)
A rating of the initial light output of a bulb, rated after 100 hrs of operation. Lumens are a measure of how much light falls on one square foot of area, one foot away from the light source.
1170
Bulb Finish
The surface finish of a bulb, which may affect the quality of the light emitted.
Opaque
Bulb Technology
The technology implemented by the bulb, e.g. incandescent, halogen, LED
LED
Average Rated Life (hr)
A measurement of the average length of time, between first use and the point when 50% of the lamps tested have stopped functioning, , using an operating cycle of 3 hours on, 20 minutes off.
50000
Operating Temperature (°F)
The ambient temperature in which the product can safely operate.
-4 to 95
Beam Angle (°)
The width of a light beam, expressed in degrees. The beam angle is often part of the ordering code for reflector lamps. For example, a 50PAR30/HIR/NFL25 is a 50-watt PAR30 narrow flood lamp with a beam angle of 25 degrees.
360
Bulb Power Type
Defines how a lamp is powered, whether it needs a ballast or not, or can use either
Hybrid
Length (in)
Also referred to as "Maximum Overall Length" (MOL). For light bulbs, it measures the length of a light bulb, from the top of the bulb to the bottom of the base or pins and is typically expressed in inches. For light fixtures and ballasts, it applies to the total horizontal length of the item.
6.9
Diameter (in)
Light bulbs: a measurement of a bulb's width taken at the widest point of the bulb. Fixtures: the measurement across the widest point of a circular fixture.
1.4
Orientation
The angle that the fixture can be mounted at
Any

Warranty

5 year limited
Damp Location
Suitable for an exterior or interior location that is subject to condensation of moisture in, on or adjacent to electrical equipment
Yes