Bulbs.com

243 Stafford St.

Worcester, MA 01603

Tel. 1 (888) 455-2800

Fax 1.508.363.2900

www.bulbs.com

The Business Lighting Experts

Satco 21 Watt A-23 LED Lamp, Wet Location Rated, 5000K

SKU: S12452 | Ordering Code: 21A23/FR/LED/E26/850/120V/ND  | UPC: 045923124525

$12.59each
Add to Cart
Save to BulbTrack ?

Quickly and easily order the products you have purchased in the past or plan to order in the future by simply adding them to your My BulbTrack page.

Once a product has been added to My BulbTrack, ordering it is as easy as entering the quantity or clicking on the product image. You can even add notes to each product to record where it is used in your business or home.

In StockReady to ship

Add 8 to your cart to get free ground shipping *

Options

Color Temperature (Kelvin)
Color Temperature Guide 3000 4000 5000

Product Highlights

  • Energy efficient replacement for a conventional 200 watt bulb
  • Estimated life of 13.7 years based on 3 hours use per day
  • No lead or mercury means easy and environmentally safe disposal
Description

Lighting Facts Per Bulb

Brightness 2900 lumens
Estimated Yearly Energy Cost $2.53
Based on 3 hrs/day, 11¢/kWh
Cost depends on rates and use
Life
Based on 3 hrs/day13.7 years
Light Appearance
WarmCool
5000 K
Energy Used21 watts

Satco 21 Watt A-23 LED Lamp, Wet Location Rated, 5000K

 

  • Traditiional yet contemporary look
  • Great for bare socket fixtures
  • Frost Finish
  • Wet location rated
  • 2900 lumens
  • Non-dimmable
  • 300 degree beam spread
  • Superior 80 CRI light quality
  • 3-year limited warranty
  • FCC and RoHS Compliant

 

 

Full Specs

Brand

Satco Products, Inc.
Energy Used
A rating, expressed in watts, to indicate the rate at which a lamp consumes energy. Also known as wattage value.
21 Watts
Incandescent/Halogen Equivalent
The wattage value of an incandescent or halogen lamp of similar brightness.
200 Watts
Volts
A measure of "electrical pressure" between two points. The voltage specification of an incandescent lamp is the electrical "pressure" required to drive it at its designed point. The "voltage" of a ballast (e.g. 120 V) refers to the line voltage coming from the power source and is connected to the ballast.
120
Base
The end (or ends) of the lamp that fits into the socket.
Medium (E26)
Bulb Shape
The description of the general appearance of a lamp/bulb consists of a letter(s) followed by a number. The letter indicates the shape of the bulb and the number relates to the diameter of the bulb in eighths of an inch. For example, a common household bulb is the A-19. The bulb is "A" shape and the diameter would be nineteen 8ths of an inch, or 2 3/8".
A-23
Bulb Color
The color of the light produced by a bulb
Bright White
CRI
Color Rendering Index is an international system used to rate a lamp's ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer and more accurately colors generally appear. CRI differences among lamps are not usually visible to the eye unless the difference is more than 3-5 points.
80
Color Temperature (Kelvin)
An expression of the hue of the light emitted, measured in degrees Kelvin. Usually expressed by a four digit number followed by (k), such as 2700k. Higher temperatures indicate whiter, "cooler" colors, while lower temperatures indicate yellower, "warmer" colors. Some common Kelvin temperature benchmarks are 2700k (warm white), 3500k (neutral white), 4100k (cool white), 5000k (bright white), and 6500k (daylight).
5000
Brightness (Lumens)
A rating of the initial light output of a bulb, rated after 100 hrs of operation. Lumens are a measure of how much light falls on one square foot of area, one foot away from the light source.
2900
Bulb Finish
The surface finish of a bulb, which may affect the quality of the light emitted.
Frosted
Bulb Technology
The technology implemented by the bulb, e.g. incandescent, halogen, LED
LED
Average Rated Life (hr)
A measurement of the average length of time, between first use and the point when 50% of the lamps tested have stopped functioning, , using an operating cycle of 3 hours on, 20 minutes off.
15000
Operating Temperature (°F)
The ambient temperature in which the product can safely operate.
-4 to 113
Beam Angle (°)
The width of a light beam, expressed in degrees. The beam angle is often part of the ordering code for reflector lamps. For example, a 50PAR30/HIR/NFL25 is a 50-watt PAR30 narrow flood lamp with a beam angle of 25 degrees.
300
Length (in)
Also referred to as "Maximum Overall Length" (MOL). For light bulbs, it measures the length of a light bulb, from the top of the bulb to the bottom of the base or pins and is typically expressed in inches. For light fixtures and ballasts, it applies to the total horizontal length of the item.
5.6
Diameter (in)
Light bulbs: a measurement of a bulb's width taken at the widest point of the bulb. Fixtures: the measurement across the widest point of a circular fixture.
2.96

Manufacturer Warranty

3 year limited
Wet Location
Suitable for exterior or interior location in which uncontrolled liquid may drip, splash or flow on or against electrical equipment.
Yes