Bulbs.com

243 Stafford St.

Worcester, MA 01603

Tel. 1 (888) 455-2800

Fax 1.508.363.2900

www.bulbs.com

The Business Lighting Experts

TCP 14W Frosted ED17 HID Replacement LED Filament Lamp, 50W Equivalent, 5000K, E26 Base,Ballast Bypass

SKU: FED17N05050E26FR | Ordering Code: ED17 50K E26 FROST

$50.99$44.99each
You save 11%
Bulb
Add to Cart
Save to BulbTrack ?

Quickly and easily order the products you have purchased in the past or plan to order in the future by simply adding them to your My BulbTrack page.

Once a product has been added to My BulbTrack, ordering it is as easy as entering the quantity or clicking on the product image. You can even add notes to each product to record where it is used in your business or home.

Clearance ItemOnly 11 left in stock. Will not be re-stocked. Typically ships within one business day.

Add 3 to your cart to get free ground shipping *

Product Highlights

  • Energy efficient replacement for a 50 watt HID bulb
  • Estimated life of 45.7 years based on 3 hours use per day
  • No lead or mercury means easy and environmentally safe disposal
Description

Lighting Facts Per Bulb

Brightness 2500 lumens
Estimated Yearly Energy Cost $1.69
Based on 3 hrs/day, 11¢/kWh
Cost depends on rates and use
Life
Based on 3 hrs/day45.7 years
Light Appearance
WarmCool
5000 K
Energy Used14 watts
  • Clearance

TCP 14W Frosted ED17 HID Replacement LED Filament Lamp, 50W Equivalent, 5000K, E26 Base,Ballast Bypass

  • Perfect for use in large retail facilities or any area where high lumens are required
  • Many applications including high bay, low bay, bollards, wall packs, garages, parking structures, decorative fixtures
  • No ballast needed
  • Instant start - No waiting for the bulb to warm up or time off between re-starts
  • Smaller than corn cob lamps for easier installation
  • Produces less heat while operating compared to corn cob lamps
  • For use in open or enclosed fixtures
  • Universal burning position
  • Can be used indoors or outdoors in weather approved fixtures
Full Specs

Brand

TCP
Energy Used
A rating, expressed in watts, to indicate the rate at which a lamp consumes energy. Also known as wattage value.
14 Watts
HID Equivalent
The wattage value of a High Intensity Discharge (HID) bulb of similar brightness.
50
Volts
A measure of "electrical pressure" between two points. The voltage specification of an incandescent lamp is the electrical "pressure" required to drive it at its designed point. The "voltage" of a ballast (e.g. 120 V) refers to the line voltage coming from the power source and is connected to the ballast.
120-277
Base
The end (or ends) of the lamp that fits into the socket.
Medium (E26)
Bulb Shape
The description of the general appearance of a lamp/bulb consists of a letter(s) followed by a number. The letter indicates the shape of the bulb and the number relates to the diameter of the bulb in eighths of an inch. For example, a common household bulb is the A-19. The bulb is "A" shape and the diameter would be nineteen 8ths of an inch, or 2 3/8".
ED-17
Bulb Color
The color of the light produced by a bulb
Bright White
CRI
Color Rendering Index is an international system used to rate a lamp's ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer and more accurately colors generally appear. CRI differences among lamps are not usually visible to the eye unless the difference is more than 3-5 points.
80
Color Temperature (Kelvin)
An expression of the hue of the light emitted, measured in degrees Kelvin. Usually expressed by a four digit number followed by (k), such as 2700k. Higher temperatures indicate whiter, "cooler" colors, while lower temperatures indicate yellower, "warmer" colors. Some common Kelvin temperature benchmarks are 2700k (warm white), 3500k (neutral white), 4100k (cool white), 5000k (bright white), and 6500k (daylight).
5000
Brightness (Lumens)
A rating of the initial light output of a bulb, rated after 100 hrs of operation. Lumens are a measure of how much light falls on one square foot of area, one foot away from the light source.
2500
Bulb Finish
The surface finish of a bulb, which may affect the quality of the light emitted.
Clear
Bulb Technology
The technology implemented by the bulb, e.g. incandescent, halogen, LED
LED
Average Rated Life (hr)
A measurement of the average length of time, between first use and the point when 50% of the lamps tested have stopped functioning, , using an operating cycle of 3 hours on, 20 minutes off.
50000
Operating Temperature (°F)
The ambient temperature in which the product can safely operate.
-22 to 104
Beam Angle (°)
The width of a light beam, expressed in degrees. The beam angle is often part of the ordering code for reflector lamps. For example, a 50PAR30/HIR/NFL25 is a 50-watt PAR30 narrow flood lamp with a beam angle of 25 degrees.
360
Bulb Power Type
Defines how a lamp is powered, whether it needs a ballast or not, or can use either
Ballast Bypass
Length (in)
Also referred to as "Maximum Overall Length" (MOL). For light bulbs, it measures the length of a light bulb, from the top of the bulb to the bottom of the base or pins and is typically expressed in inches. For light fixtures and ballasts, it applies to the total horizontal length of the item.
5.4
Diameter (in)
Light bulbs: a measurement of a bulb's width taken at the widest point of the bulb. Fixtures: the measurement across the widest point of a circular fixture.
2.2

Manufacturer Warranty

5 year limited
Rated for Fully Enclosed Fixtures
Not all LED bulbs are suitable for use in enclosed fixtures, due to the amount of heat they generate. Rated bulbs have been tested and approved as safe for enclosed fixtures.
Yes