The LED Authority

Philips Bodine B30 Linear Fluorescent Emergency Ballast For 1-2 Lamps, 17-215 Watts, 900-3500 Lumens

SKU: B30 | Ordering Code: B30  | UPC: 663015101485

$319.99 per Ballast
Add to Cart
Save to BulbTrack ?

My BulbTrack

Finding the lighting solutions you need might be simple at, but buying them is even easier. Thanks to our exclusive BulbTrack feature, you can quickly and easily order the products you have purchased in the past or plan to order in the future by simply adding them to your My BulbTrack page. Products are added to your My BulbTrack page when you check out from your shopping cart or add them from the product description pages.

Once a product has been added to My BulbTrack, ordering it is as easy as entering the quantity or clicking on the product image. You can even add notes to each product to record where it is used in your business or home. Make buying your replacement lighting as simple as it should be. Create your BulbTrack today!

In Stock

This item qualifies for free ground shipping *

Product Highlights

  • Ignites up to two T5, T8, T9, T10, T12, 4-pin lamps

Philips Bodine B30 fluorescent emergency ballast works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The emergency ballast consists of a nickel-cadmium battery, charger and electronic circuitry in one case. When AC power fails, the B30 immediately switches to the emergency mode, operating either one or two lamps at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp life shutdown circuits. 

  • Can be used with most 17-215 watt (2'-8') T5, T8, T9, T10 or T12 fluorescent lamps without integral starters, including Ubent, HO, VHO, circline, energy saving and rapid start (4-pin) compact fluorescent lamps
  • Can be used with either switched or unswitched fixtures
  • Produces 900 to 3500 lumens of initial emergency light output, depending on the number of lamps (one or two), wattage and type of lamps
  • Suitable for indoor and damp locations
  • Battery
    • High temperature maintenance free
    • Nickel-Cadmium
    • 7-10 year life expectancy
  • Recharge time - 24 hours
  • Ambient temperature - 32ºF - 122ºF
  • Two-wire illuminated test switch
  • AC input current - 110mA
  • Illumination time - 90 minutes

B30 Lamp Compatibility:

  • 1-2 lamp, 17-40 watt, 2'-4', T8, T9, T10 and T12, single or bipin base
  • 1 lamp, 40-215 watt, 5'-8', T8, T9, T10 and T12, single or bipin base
  • 1 lamp, 18-55 watt, long compact 4-pin (2G11) base
  • 1 lamp, 18-42 watt, twin/quad/triple, twin-tube compact, 4-pin (G24q, GX24q) base
  • 1 lamp, 8.5-16.5 watt, 2'-4', Philips InstantFit LED T8, bipin base
  • 1 lamp, 16.5 watt, Philips InstantFit LED T8 U-bend 6", bipin base
  • 1 lamp, 16.5 watt, 22", Philips InstantFit LED twin-tube compact, 4-pin base
  • 1 lamp, 16-55 watt, 2D, 4-pin (GR10g) base
  • 1 lamp, 22-55 watt, T5 HO, HO circline 4-pin (2GX13) base
  • 1 lamp, 24-54 watt, 2'-4', T5HO, miniature bipin base
  • 1 lamp, 14-35 watt, 2'-5', T5, miniature bipin base
Full Specs



Input Volts


Initial Lumen Output

The lumen output at first start-up.
Initial Lumen Output

Number of Lamps


Ballast Type

Magnetic ballasts are a legacy technology and use inductance to transform the line voltage to the voltage required to "fire" or excite the gasses in a lamp. Electronic ballasts use a variety of starting methods, and are more efficient than magnetic ballasts in converting input power to the proper lamp power and operate fluorescent lamps at higher frequencies, resulting in an overall lamp-ballast system – increasing efficacy 15% to 20% over a magnetic equivalent.
Ballast Type

Length (in)

Also referred to as "Maximum Overall Length" (MOL). For light bulbs, it measures the length of a light bulb, from the top of the bulb to the bottom of the base or pins and is typically expressed in inches. For light fixtures and ballasts, it applies to the total horizontal length of the item.
Length (in)

Width (in)

For fixtures and ballasts, width is the measurement of the total horizontal distance from left to right of the product in inches.
Width (in)

Height (in)

For ballasts and fixtures, height is the measurement of total vertical distance from the top of the product to the bottom expressed in inches.
Height (in)

Lamps by Wattage

1x19W-55W, 140-1215, 2x17W-40W


5 year limited

Ballast Lamp Type

The type of bulb the ballast can fire.
Ballast Lamp Type
T5, T8, T9, T10, T12, 4-pin

AC Input (Watts)

The amount of watts to operate emergency lamps.
AC Input (Watts)

Charging Current (Amps)

The amount of current to charge a battery.
Charging Current (Amps)