Bulbs.com

243 Stafford St.

Worcester, MA 01603

Tel. 1 (888) 455-2800

Fax 1.508.363.2900

www.bulbs.com

The Business Lighting Experts

Green Creative 15W Color Selectable Ballast Bypass Emergency LED Tube

SKU: 37410 | Ordering Code: 15T8/4F/8CCTS/EM  | UPC: 790492374108

$98.99each
Add to Cart
Save to BulbTrack ?

Quickly and easily order the products you have purchased in the past or plan to order in the future by simply adding them to your My BulbTrack page.

Once a product has been added to My BulbTrack, ordering it is as easy as entering the quantity or clicking on the product image. You can even add notes to each product to record where it is used in your business or home.

In StockReady to ship

Add 2 to your cart to get free ground shipping *

Product Highlights

  • Estimated life of 45.7 years based on 3 hours use per day
  • No lead or mercury means easy and environmentally safe disposal
  • Adjustable color
Description
  • DLC
    Listed
  • Color
    Selectable

Green Creative 15W Color Selectable (3500K/4000K/5000K) Ballast Bypass Emergency LED Tube

The lamp can be used as a normal linear LED tube with double ended wiring for bypass application, supporting on/off switching operation at normal 120-277V power supply.

  • Replaces 4’ T8 fluorescent lamp
  • Operates directly on 120-277V line voltage
  • SelectKelvin switch for CCT adjustment
  • Continuous self-test design to ensure tube safety
  • Shatter proof Polycarbonate and aluminum 
  • 3500K / 4000K / 5000K CCT adjustable
  • L70 rated lifetime up to 50,000 hours, 5 years limited warranty
  • Two input sides, one to power the standard mode and the other to power the EM mode
  • Built-in recyclable Lithium battery for emergency lighting
  • Constant power output in emergency mode for a minimum of 90 minutes

 

Product Documents

Full Specs

Brand

Green Creative

Model Number

15T8/4F/8CCTS/EM
Energy Used
A rating, expressed in watts, to indicate the rate at which a lamp consumes energy. Also known as wattage value.
15 Watts
Fluorescent Equivalent
The total wattage of fluorescent lamps in a fixture that this fixture replaces.
32
Volts
A measure of "electrical pressure" between two points. The voltage specification of an incandescent lamp is the electrical "pressure" required to drive it at its designed point. The "voltage" of a ballast (e.g. 120 V) refers to the line voltage coming from the power source and is connected to the ballast.
120-277
Base
The end (or ends) of the lamp that fits into the socket.
Medium Bipin
Wiring
Wiring configuration a bulb can work with. Can be single-ended, double-ended or both.
Double Ended
Bulb Shape
The description of the general appearance of a lamp/bulb consists of a letter(s) followed by a number. The letter indicates the shape of the bulb and the number relates to the diameter of the bulb in eighths of an inch. For example, a common household bulb is the A-19. The bulb is "A" shape and the diameter would be nineteen 8ths of an inch, or 2 3/8".
T-8
Bulb Color
The color of the light produced by a bulb
Neutral White/Cool White/Bright White
CRI
Color Rendering Index is an international system used to rate a lamp's ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer and more accurately colors generally appear. CRI differences among lamps are not usually visible to the eye unless the difference is more than 3-5 points.
82
Color Temperature (Kelvin)
An expression of the hue of the light emitted, measured in degrees Kelvin. Usually expressed by a four digit number followed by (k), such as 2700k. Higher temperatures indicate whiter, "cooler" colors, while lower temperatures indicate yellower, "warmer" colors. Some common Kelvin temperature benchmarks are 2700k (warm white), 3500k (neutral white), 4100k (cool white), 5000k (bright white), and 6500k (daylight).
3500/4000/5000
Lowest Color Temperature (Kelvin)
The warmest color temperature that can be set for a color-tuneable product.
3500
Highest Color Temperature (Kelvin)
The coolest color temperature that can be set for a color-tuneable product.
5000
Brightness (Lumens)
A rating of the initial light output of a bulb, rated after 100 hrs of operation. Lumens are a measure of how much light falls on one square foot of area, one foot away from the light source.
1900/2000
Bulb Finish
The surface finish of a bulb, which may affect the quality of the light emitted.
Opaque
Bulb Technology
The technology implemented by the bulb, e.g. incandescent, halogen, LED
LED
Average Rated Life (hr)
A measurement of the average length of time, between first use and the point when 50% of the lamps tested have stopped functioning, , using an operating cycle of 3 hours on, 20 minutes off.
50000
Operating Temperature (°F)
The ambient temperature in which the product can safely operate.
32 to 113
Beam Angle (°)
The width of a light beam, expressed in degrees. The beam angle is often part of the ordering code for reflector lamps. For example, a 50PAR30/HIR/NFL25 is a 50-watt PAR30 narrow flood lamp with a beam angle of 25 degrees.
140
Bulb Power Type
Defines how a lamp is powered, whether it needs a ballast or not, or can use either
Ballast Bypass
Length (in)
Also referred to as "Maximum Overall Length" (MOL). For light bulbs, it measures the length of a light bulb, from the top of the bulb to the bottom of the base or pins and is typically expressed in inches. For light fixtures and ballasts, it applies to the total horizontal length of the item.
48
Diameter (in)
Light bulbs: a measurement of a bulb's width taken at the widest point of the bulb. Fixtures: the measurement across the widest point of a circular fixture.
1
Socket Type
Type of socket a linear lamp is compatible with, whether shunted, non-shunted or both.
Non Shunted

Warranty

5 year limited
Damp Location
Suitable for an exterior or interior location that is subject to condensation of moisture in, on or adjacent to electrical equipment
Yes
DLC Listing
Approved by the DesignLights Consortium, a collaboration of utility companies and regional energy efficiency organizations. Approved products meet the consortium's standards for ensuring high-quality, energy-efficient lighting design. There are three categories, Standard, Premium and Horticultural, plus Luna for light-pollution minimization.
S-NCHZQ9 Standard
Rated for Fully Enclosed Fixtures
Not all LED bulbs are suitable for use in enclosed fixtures, due to the amount of heat they generate. Rated bulbs have been tested and approved as safe for enclosed fixtures.
Yes
Battery Backup
Has a backup battery to allow it to continue functioning in case of power failure.
Yes
Color Selectable
Bulb is capable of emitting several different colors that are selectable by the user after it has been installed.
Yes