Bulbs.com

243 Stafford St.

Worcester, MA 01603

Tel. 1 (888) 455-2800

Fax 1.508.363.2900

www.bulbs.com

The Business Lighting Experts

Lunera 14W 48" T8 5000K Glass LED Bulb, Ballast Bypass, Can Be Used With Shunted or Non-Shunted Sockets

SKU: 932-00130 | Ordering Code: HN-T8-L-48-14W-850-G1-UT  | UPC: 815975022885

Sorry, this product is not available to purchase.

Product Highlights

  • Estimated life of 45.7 years based on 3 hours use per day
  • No lead or mercury means easy and environmentally safe disposal
Description

Lighting Facts Per Bulb

Brightness 1800 lumens
Estimated Yearly Energy Cost $1.69
Based on 3 hrs/day, 11¢/kWh
Cost depends on rates and use
Life
Based on 3 hrs/day45.7 years
Light Appearance
WarmCool
5000 K
Energy Used14 watts
  • DLC
    Listed

Lunera T8 5000K bright white 14 watt non-dimmable glass LED lamps is a double-ended ballast bypass replacement for a 4 ft. bi-pin T8 fluorescent lamp up to 32 watts. Lunera's integrated Universal Tombstone Tewchnology (UTT) makes this a double-ended lamp, allowing installation into both shunted and non-shunted G13 tombstones. Built-in universal driver allows lamp operation at 120V-277V. 

Line Driven - Ballast must be bypassed when present.

Can be used with shunted or non-shunted sockets.

  • Non-Dimmable
  • Replacement for:
    • F32T8 32W
    • F32T8 30W
    • F32T8 28W
    • F32T8 25W
  • Perfect for applications with frequent "on/off" switching cycles, and buildings that desire to be mercury free
  • Power must be turned off at the fixture before bypassing the ballast and replacing the lamp
  • Instant on, no flicker or buzz
  • Emits virtually no UV rays or IR
  • Suitable for damp locations
Full Specs

Brand

Lunera Lighting

Model Number

HN-T8-L-48-14W-850-G1-UT
Energy Used
A rating, expressed in watts, to indicate the rate at which a lamp consumes energy. Also known as wattage value.
14 Watts
Volts
A measure of "electrical pressure" between two points. The voltage specification of an incandescent lamp is the electrical "pressure" required to drive it at its designed point. The "voltage" of a ballast (e.g. 120 V) refers to the line voltage coming from the power source and is connected to the ballast.
120-277
Base
The end (or ends) of the lamp that fits into the socket.
Medium Bipin
Bulb Shape
The description of the general appearance of a lamp/bulb consists of a letter(s) followed by a number. The letter indicates the shape of the bulb and the number relates to the diameter of the bulb in eighths of an inch. For example, a common household bulb is the A-19. The bulb is "A" shape and the diameter would be nineteen 8ths of an inch, or 2 3/8".
T-8
Bulb Color
The color of the light produced by a bulb
Bright White
CRI
Color Rendering Index is an international system used to rate a lamp's ability to render object colors. The higher the CRI (based upon a 0-100 scale) the richer and more accurately colors generally appear. CRI differences among lamps are not usually visible to the eye unless the difference is more than 3-5 points.
80
Color Temperature (Kelvin)
An expression of the hue of the light emitted, measured in degrees Kelvin. Usually expressed by a four digit number followed by (k), such as 2700k. Higher temperatures indicate whiter, "cooler" colors, while lower temperatures indicate yellower, "warmer" colors. Some common Kelvin temperature benchmarks are 2700k (warm white), 3500k (neutral white), 4100k (cool white), 5000k (bright white), and 6500k (daylight).
5000
Brightness (Lumens)
A rating of the initial light output of a bulb, rated after 100 hrs of operation. Lumens are a measure of how much light falls on one square foot of area, one foot away from the light source.
1800
Bulb Finish
The surface finish of a bulb, which may affect the quality of the light emitted.
Opaque
Bulb Technology
The technology implemented by the bulb, e.g. incandescent, halogen, LED
LED
Average Rated Life (hr)
A measurement of the average length of time, between first use and the point when 50% of the lamps tested have stopped functioning, , using an operating cycle of 3 hours on, 20 minutes off.
50000
Operating Temperature (°F)
The ambient temperature in which the product can safely operate.
-40 to 104
Beam Angle (°)
The width of a light beam, expressed in degrees. The beam angle is often part of the ordering code for reflector lamps. For example, a 50PAR30/HIR/NFL25 is a 50-watt PAR30 narrow flood lamp with a beam angle of 25 degrees.
330
Bulb Power Type
Defines how a lamp is powered, whether it needs a ballast or not, or can use either
Ballast Bypass
Length (in)
Also referred to as "Maximum Overall Length" (MOL). For light bulbs, it measures the length of a light bulb, from the top of the bulb to the bottom of the base or pins and is typically expressed in inches. For light fixtures and ballasts, it applies to the total horizontal length of the item.
48
Diameter (in)
Light bulbs: a measurement of a bulb's width taken at the widest point of the bulb. Fixtures: the measurement across the widest point of a circular fixture.
1

Warranty

5 year limited
Damp Location
Suitable for an exterior or interior location that is subject to condensation of moisture in, on or adjacent to electrical equipment
Yes
DLC Listing
Approved by the DesignLights Consortium, a collaboration of utility companies and regional energy efficiency organizations. Approved products meet the consortium's standards for ensuring high-quality, energy-efficient lighting design. There are three categories, Standard, Premium and Horticultural, plus Luna for light-pollution minimization.
Standard
DLC Code
Code identifying the product in DLC (DesignLights Consortium) listings.
P8PTYHP5