120-277 Volt Two Lamp F32T8 Electronic Ballast

SKU: ICN2P32N | Ordering Code: ICN2P32N (120-277V)  | UPC: 781087069127

In Stock
Price per Ballast
Each $17.99
Ballasts per Case
30
 x 
Add to Cart
Save to BulbTrack ?

My BulbTrack

Finding the lighting solutions you need might be simple at Bulbs.com, but buying them is even easier. Thanks to our exclusive BulbTrack feature, you can quickly and easily order the products you have purchased in the past or plan to order in the future by simply adding them to your My BulbTrack page. Products are added to your My BulbTrack page when you check out from your shopping cart or add them from the product description pages.

Once a product has been added to My BulbTrack, ordering it is as easy as entering the quantity or clicking on the product image. You can even add notes to each product to record where it is used in your business or home. Make buying your replacement lighting as simple as it should be. Create your BulbTrack today!

 
Description
Advance Centium® Electronic Instant Start Ballast Ignites One or Two F17T8, FB017T8 Lamps, F25T8, FB025T8, FB031T8, F32T8, FB032T8 or One F40T8 Lamp(s) of 120-277 Voltage. LAMP(S) NOT INCLUDED.
Full Specs

Product Details

Brand

Advance Transformer

Product Line

Centium

Input Volts

120/277

Input Watts

21-59

Number of Lamps

1/2

Ballast Factor

The percentage of a lamp's rated lumen output that can be expected when operated on a specific commercially available ballast. For example, a ballast with a ballast factor of 0.93 will result in the lamps emitting 93% of their rated lumen output. A ballast with a lower ballast factor results in less light output and also generally consumes less power.
 
Ballast Factor
88-108%

Ballast Type

Magnetic ballasts are a legacy technology and use inductance to transform the line voltage to the voltage required to "fire" or excite the gasses in a lamp. Electronic ballasts use a variety of starting methods, and are more efficient than magnetic ballasts in converting input power to the proper lamp power and operate fluorescent lamps at higher frequencies, resulting in an overall lamp-ballast system – increasing efficacy 15% to 20% over a magnetic equivalent.
 
Ballast Type
Electronic

Length (in)

Also referred to as "Maximum Overall Length" (MOL). For light bulbs, it measures the length of a light bulb, from the top of the bulb to the bottom of the base or pins and is typically expressed in inches. For light fixtures and ballasts, it applies to the total horizontal length of the item.
 
Length (in)
9.5

Width (in)

For fixtures and ballasts, width is the measurement of the total horizontal distance from left to right of the product in inches.
 
Width (in)
1.3

Height (in)

For ballasts and fixtures, height is the measurement of total vertical distance from the top of the product to the bottom expressed in inches.
 
Height (in)
1

Power Factor

99%

Total Harmonic Distortion (THD)

Total harmonic distortion, or THD, is the measure of how much a ballast can distort the waveform of that building’s power supply and interfere with other equipment. Electronic ballasts today are rated at less than 20 percent, 15 percent, or less than 10 percent THD. The magnetic ballast is rated in the 20 to 28 percent range. The lower the THD the better and more efficient the ballast, and the less likely it is to interfere with other electronic equipment.
 
Total Harmonic Distortion (THD)
10%

Lamps by Wattage

1x17W, 1x25W, 1x31W, 1x32W, 1x40W, 2x17W, 2x25W, 2x31W, 2x32W

Ballast Lamp Type

The type of bulb the ballast can fire.
 
Ballast Lamp Type
T8
Reviews

REVIEW SNAPSHOT®

by PowerReviews
Advance Transformer120-277 Volt Two Lamp F32T8 Electronic Ballast
 
5.0

(based on 1 review)

Reviewed by 1 customer

Displaying review 1

Back to top

 
5.0

Used To Upgrade An Old Lighting Fixture

By Rick

From KY

About Me Avid Do-It-Yourselfer

Verified Buyer

Pros

  • Easy To Install
  • Improves Light Output
  • Quality Construction

Cons

    Best Uses

    • Energy savings
    • Repair or replacement

    Comments about Advance Transformer 120-277 Volt Two Lamp F32T8 Electronic Ballast:

    I had a thirty year old 2' x 2' ceiling lighting fixture in my kitchen that had two T-12 ubent florescent bulbs. This light stays on more than any fixture in my home. The bulbs were getting old and starting to flicker a bit. The bulbs are a bit of a pain to change so I decided to upgrade to LED for energy savings, longer bulb life and increased brightness. I discovered that the old ready start magnetic ballast was not compatible withe ubent Philips LED bulbs I purchased. The Bulbs.com rep picked out this ballast to be compatible with the new bulbs. This ballast fit the old mount perfectly. The old ballast was serial wired and the new one was parallel wired so I had to rewire the old unit using the old bulb holders. Following the wiring diagram that came with the new ballast it was a very simple job and did not require taking the fixture down. The new bulbs come on instantly and are much brighter and the new bulbs and ballast produce far less heat than the old ones did which to me equates to energy savings. I am very pleased with the products supplied by Bulbs.com and the assistance provided by their reps.

    • Primary use:
    • Personal

    Displaying review 1

    Back to top

    Q & A

    Do you have questions about this product?

    Get answers from real customers and in-house experts with AnswerBox.

    1 Question | 1 Answer
    Displaying question 1
    • Q:

      This ballast is an ICN2P32 N and the ballast that i am currently using is an advance ICN2P32SC. What is the difference
      Asked on 8/2/2011 by Ron Stachelek from Southbridge MA

      1 answer

      • CUSTOMER CARE

        A:

        The ICN2P32N has replaced the "SC" version. They are comparable ballasts; there is a difference in the width and height of the ballasts. This ballast is 1" in height and 1.3" in width. The "SC" version is 1.2" in height and 1.7" in width. The lengths are the same for both ballasts.

        Answered on 8/3/2011 by Product Support from Bulbs.com